Product enquiryProduct brochure

Spectroscopy Detectors - DInGaAs Series

DInGaAs Series Te Cooled InGaAs Detectors

TE cooled InGaAs detectors, spectral range from 0.8 μm to 2.6 μm.

DInGaAs (x) TE detectors have the same construction and x-1700/ 1900/ 2200/ 2400/ 2600, all use import two stage TE cooled InGaAs detectors.

Professional DInGaAs Series detectors

DInGaAs series detectors are slit mount design, are room temperature, and high performance. InGaAs detectors operate over the NIR range from 0.8 μm to 1.7 μm. The DInGaAs1600, DInGaAs1650 and the DInGaAs1700 detectors all have the same construction design.

Each unit is compatible with the Omni- family of monochromators exit slit.

DInGaAs (x) TE detectors have the same construction and x-1700/ 1900/ 2200/ 2400/ 2600, all use import two stage TE cooled InGaAs detectors. DInGaAs 3800 detector is also available. Please see specifications tab.

DInGaAs 1600 / 1700

PARAMETER TEST CONDITION DINGAAS1600 TEST CONDITION DINGAAS 1650 TEST CONDITION DINGAAS 1700 UNIT
MIN TYP MAX MIN TYP MAX MIN TYP MAX
Active Diameter   1.5   5   5 mm
spectral Range   900 - 1600   800 - 1650   800 - 1700 nm
Re             0.1 0.2   A / W
VR = 0V@ 1300 nm 0.8 0.85   VR = 10V@1300 nm - 0.8 - @ 850 nm 0.8 0.9  
VR = 0V@ 1550 nm 0.9 0.9   VR = 0V@ 1550 nm - 0.8 - @ 1300 nm   0.9  
Dark Current VR = 0V   0.1 1     10   VR - 0V   5 10 lo (nA)
NEP  2.8 x 10¯¹³         @ 1550 nm 0.3     pWHz-1/2
Signal Output   Current   Current   Current  

DInGaAs 1700TE / 1900 / 2200TE / 2400TE / 2600TE

  DINGAAS
1700TE
DINGAAS
1900 TE
DINGAAS
2200TE
DINGAAS
2400TE
DINGAAS
2600TE
UNIT
Active Size Diameter 3 3 3 3 3 mm
spectral Range 800 - 1700 800 - 1900 800 - 2200 800 - 2400 800 - 2600 nm
Peak Responsivity 0.9 1 1.1 1.15 1.2 A/W
Peak D* (cmHz¯½/ W) @ 1kHz typ 8.4 x 10¹¹ 9.1 x 10¹² 1.9 x 10¹² 9.6 x 10¹¹ 4.9 x 10¹¹  
NEP (W/Hz¯½) @ Peak Wavelength typ 3.2 x 10¯¹³ 2.9 x 10¯¹⁴ 1.4 x 10¯¹³ 2.8 x x10¯¹³ 5.5 x 10¯¹³ pWHz-1/2
Temperature Controller ZTC ZTC ZTC ZTC ZTC  
Signal Output Current Current Current Current Current ºC
Operating Temperature -40 -40 -40 -40 -40 ºC
Temperature Stability ± 0.5 ± 0.5 ± 0.5 ± 0.5 ± 0.5 ºC
Ambient Temperature + 10 -+ 40 + 10 -+ 40 + 10 -+ 40 + 10 -+ 40 + 10 -+ 40 ºC
Output Signal Polarity P P P P P -
Remarks In the cooled mode, the detectors must be working with temperature controller (ZTC) Tranc-impedance amplifier ZAMP is recommended -

DInGaAs 3800 / 3800TE

  DINGAAS 3800 DINGAAS 3800 - TE UNIT
Active Diameter 2 2 mm
Spectral Range 1 - 3.8 1 - 3.8 μm
Re 0.8 1.5 A / W
D* (@ λpeak, 1KHz)cm 2.5 x 10⁹ 9.1 x 10¹² Hz½ W¯¹
NEP (@ λpeak, 1KHz)p 71 4.4 W Hz½
Temperature Model - ZTC -2  
Detector Temperature Room temperature -40 ºC
Temperature Stability - ± 0.5 ºC
Signal Output Mode Current Current  
Signal Output Level P P  

DinGaAs Detectors Application Advice

  • DinGaAs series and  DInGaAs - TE series detectors are in current output mode, before connecting to the signal processors such as oscilloscope or lock-in amplifier, the IV-Trans-impedance Amplifier ZAMP is proposed to be connected as a preamp which can convert the current signal to voltage signal. If the signal processor indicates that is can be input correct signal, you can connect the detectors to the signal directly. In order to improve the detection sensitivity, the IV Tranc- Impedance Amplifier is recommended.
  • DInGaAs series and DInGaAs-TE series detectors used with the DCS103 data acquisition system, the IV-Trans-impedance Amplifier is recommended in order to improve the detection sensitivity.
  • DInGaAs series and DInGaAs-TE series detectors used with the DSC300PA data acquisition system, as signal amplifier has been integrated in the DCS300PA dual-channel; it does not need to match a preamplifier.
  • In the TE cooled mode, DInGaAs-TE series detectors must work with Temperature controller (ZTC) for cooling control.
Spectroscopy Detectors - DInGaAs Series
 

Other Popular Products

  • Single Channel DetectorSingle Channel Detector
    Single channel detector, spectral coverage is UV-VIS-IR spectrum
    View Details
  • Silicon DetectorSilicon Detector